DynaPro is suitable for a variety of segments due to its scalable architecture that envoles with your needs and secure your investment. Choose your combination of user units and power units based on your current power output demand – you can always add and upgrade more units in the future.
Dynamics versatility offers nearly limitless possibilities for EV charging.
AC input
Input rating
400 VAC ± 15%
Input voltage
400V
AC input connection
3P + N + PE
Max. input current (A)
660A
Frequency (Hz)
45~65
Power factor
>0.99 @ 50% or higher load
Input power
180kW
Effciency (%)
95
DC output
Output voltage range
150~1000Vdc (CCS)
Max. output current
500A
Output power range(kW)
350kW
Voltage accuracy (%)
± 0.5
Current accuracy (%)
± 1
User interface & control
Display
7 inch touch screen
Push buttons
Emergency stop
User authentication
RFID system ISO/IEC14443A/B
Display Information
Charging process and status / alarm and warning messages
Communication
External
Ethernet/4G/3G
Internal
CANbus / RS485
Environmental
Operating Temperature (°C)
-30 ~ +50, power derating from 50 and above
Humidity (%)
5~95RH, non-condensing
Altitude (m)
≤2500m
IP Level
IP54
Cooling Method
Liquid cooling
Mechanical
Dimension(WxDxH mm)
820*800*1980
Weight(kg)
≤650
Cable Length(m)
5
Protection
Input protection
OVP, OCP, OTP, OPP, UVP, Residual current detection, Surge protection, Cabinet-open detection
Output protection
SCP, OVP, OCP, OTP, UVP, Residual current detection
Regulation
Certificate
CE
Safety
IEC 61851-1:2017, IEC 61851-23, IEC 61851-24,
Charging Interface
DIN70121, ISO15118
AC input
Input rating
400 VAC ± 15%
Input voltage
400V
AC input connection
3P + N + PE
Max. input current (A)
660A
Frequency (Hz)
45~65
Power factor
>0.99 @ 50% or higher load
Input power
180kW
Effciency (%)
95
DC output
Output voltage range
150~1000Vdc (CCS)
Max. output current
200A
Output power range(kW)
300kW
Voltage accuracy (%)
± 0.5
Current accuracy (%)
± 1
User interface & control
Display
7 inch touch screen
Push buttons
Emergency stop
User authentication
RFID system ISO/IEC14443A/B
Display Information
Charging process and status / alarm and warning messages
Communication
External
Ethernet/4G/3G
Internal
CANbus / RS485
Environmental
Operating Temperature (°C)
-30 ~ +50, power derating from 50 and above
Humidity (%)
5~95RH, non-condensing
Altitude (m)
≤2500m
IP Level
IP55
Cooling Method
Fan cooling
Mechanical
Dimension(WxDxH mm)
300*396*1505
Weight(kg)
≤78
Cable Length(m)
5 (ccs1, ccs2, CHAdeMO)
Protection
Input protection
OVP, OCP, OTP, OPP, UVP, Residual current detection, Surge protection, Cabinet-open detection
Output protection
SCP, OVP, OCP, OTP, UVP, Residual current detection
Regulation
Certificate
CE, TR25
Safety
IEC 61851-1:2017, IEC 61851-23, IEC 61851-24,
Charging Interface
DIN70121, ISO15118
AC input
Input rating
400 VAC ± 15%
Input voltage
400V
AC input connection
3P + N + PE
Max. input current (A)
660A
Frequency (Hz)
45~65
Power factor
>0.99 @ 50% or higher load
Input power
180kW
Efficiency (%)
95
DC output
Output voltage range
150~1000Vdc (CCS)
Max. output current
500A
Output power range(kW)
350kW
Voltage accuracy (%)
± 0.5
Current accuracy (%)
± 1
User interface & control
Display
7 inch touch screen
Push buttons
Emergency stop
User authentication
RFID system ISO/IEC14443A/B
Display Information
Charging process and status / alarm and warning messages
Communication
External
Ethernet/4G/3G
Internal
CANbus / RS485
Environmental
Operating Temperature (°C)
-30 ~ +50, power derating from 50 and above
Humidity (%)
5~95RH, non-condensing
Altitude (m)
≤2500m
IP Level
IP55
Cooling Method
Liquid cooling
Mechanical
Dimension(WxDxH mm)
600*380*2300
Weight(kg)
≤150
Cable Length(m)
5
Protection
Input protection
OVP, OCP, OTP, OPP, UVP, Residual current detection, Surge protection, Cabinet-open detection
Output protection
SCP, OVP, OCP, OTP, UVP, Residual current detection
Regulation
Certificate
CE
Safety
IEC 61851-1:2017, IEC 61851-23, IEC 61851-24,
Charging Interface
DIN70121, ISO15118